Sign In | Join Free | My burrillandco.com
Home > MVR Evaporator >

Tubular Type Exchanger Forced Circulation MVR Evaporator

Jiangsu Hanpu Mechanical Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Tubular Type Exchanger Forced Circulation MVR Evaporator from wholesalers
     
    Buy cheap Tubular Type Exchanger Forced Circulation MVR Evaporator from wholesalers
    • Buy cheap Tubular Type Exchanger Forced Circulation MVR Evaporator from wholesalers
    • Buy cheap Tubular Type Exchanger Forced Circulation MVR Evaporator from wholesalers
    • Buy cheap Tubular Type Exchanger Forced Circulation MVR Evaporator from wholesalers
    • Buy cheap Tubular Type Exchanger Forced Circulation MVR Evaporator from wholesalers

    Tubular Type Exchanger Forced Circulation MVR Evaporator

    Ask Lasest Price
    Brand Name : HANPU
    Model Number : MVR
    Certification : CE,ISO9001
    Price : 200,000USD~20,000,000USD
    Payment Terms : L/C,D/A,D/P,T/T,Western Union
    Supply Ability : 1 Set/3 months
    Delivery Time : 3 months
    • Product Details
    • Company Profile

    Tubular Type Exchanger Forced Circulation MVR Evaporator

    Tubular Type Exchanger · Forced Circulation MVR Evaporator
    Tubular shell-and-tube MVR evaporator with forced-circulation loop and mechanical vapor compressor

    Engineer-to-order tubular (shell-and-tube) MVR evaporator with a forced-circulation loop for high-salinity, viscous, and solids-bearing feeds. Mechanical Vapor Recompression (MVR) recycles latent heat as the primary duty, delivering low OPEX, robust heat transfer, and stable 24/7 operation for chemical, food, and environmental services.

    Key Benefits
    • Rugged thermal core: Tubular exchangers tolerate scaling/erosion better than narrow-gap plates.
    • Stable with solids: High-velocity forced circulation maintains ΔT/LMTD and limits deposition.
    • Energy saving: Electric-driven MVR minimizes fresh steam after start-up.
    • Wide duty window: Fits concentration, mother-liquor recovery, and ZLD pre-crystallization.
    • Serviceability: Straight/U-tube bundles, large clean-outs, CIP-ready design.
    Process & Thermal Economy

    Secondary vapor is mechanically compressed to elevate saturation temperature and reused as the heating medium. The forced-circulation loop provides high shear at tube walls, protecting heat-transfer coefficients across variable chemistry and viscosity while keeping specific energy low.

    Materials & Cleanability

    Wetted parts in SS316L/duplex; titanium/Hastelloy options for chloride or aggressive feeds. Drainable layouts, removable channel heads, CIP skid, and antiscalant dosing extend campaign length.

    Process Overview — Tubular FC MVR
    Flow: feed conditioning → tubular heater (forced circulation) → MVR compression → condensate polishing → concentrate handling
    • Feed conditioning: screening/filtration, softening or pH trim to mitigate scaling/corrosion.
    • Tubular heater + separator: high-velocity loop under vacuum for efficient, gentle evaporation.
    • MVR compression: VFD-driven compressor sets discharge pressure (ΔT) and capacity.
    • Condensate polishing: filters/RO/AC to reuse or compliant discharge (conductivity/TOC guard).
    • Concentrate routing: to crystallizer/centrifuge/dryer or recycle per ZLD/production needs.
    Key Components
    • Tubular shell-and-tube heater (straight/U-tube) with forced-circulation pump
    • MVR mechanical vapor compressor (turbo/Roots) with VFD
    • Vapor–liquid separator, surface condenser, vacuum/NCG handling skid
    • Preheaters/heat-recovery HX; PLC/HMI/SCADA with historian
    • CIP skid; antiscalant dosing; instrumentation (T/P/flow/cond/level)
    Performance & Sizing
    ParameterTypical Range*
    OperationContinuous, vacuum duty
    Electric use (MVR)~15–40 kWh per ton of water evaporated (duty/CR dependent)
    Shell pressure~6–25 kPa(abs), feed/ΔT dependent
    Turndown50–100% with stable ΔT and quality
    MaterialsSS316L / duplex; Ti/Hastelloy on request

    *Performance depends on feed salinity/viscosity, fouling tendency, compression ratio, and exchanger design.

    FAQ
    When choose tubular over plate/pillow plate?

    For scaling, particulates, or erosion risk, tubular exchangers provide higher robustness and allow mechanical cleaning.

    Can it integrate into our ZLD train?

    Yes—commonly paired with RO/NF upstream and crystallization/solids handling downstream.

    How is scaling managed?

    Optimized ΔT/LMTD and velocity, antiscalant dosing, scheduled CIP, and corrosion-appropriate materials (e.g., Ti for chlorides).

    Application
    Applications: high-salinity concentration, viscous feeds, and ZLD pre-crystallization with tubular forced-circulation MVR
    Quality Tubular Type Exchanger Forced Circulation MVR Evaporator for sale